西门子武汉供应商电源供应
6BK1942-0AA00-0AA0
SIPLUS HCS4200 Rack 4200 可用来容纳多 12 个 POM4220
Rack订货数据
附件
产品信息
组态工具
跳转到概述
设计
功能
技术规范
附件
更多信息
概述
SIPLUS HCS4200 heating control system
The rack constitutes the basic mechanical structure of theSIPLUS HCS4200.
设计
Rack for mounting on the cabinet rear panel
Rear bus board for holding 12 power output modules
Heat dissipation with optional fan units, that is, 1 fan moduleis required for every 4 power output modules.
功能
Rack for holding 4 or 12 power output modules.
Internal communication takes place via a bus board on therear.
Depending on the switching capacity and ambient temperature, therack may have to be force-ventilated.
The fan units are available as optional accessories (Articlenumbers 6BK1942-4AA00-0AA0 and 6BK1942-4BA00-0AA0).
For detailed information, refer to the "Heating control systemSIPLUS HCS4200 PROFINET/PROFIBUS DP" OperatingInstructions, https://support.industry.siemens.com/cs/ww/en/view/107685679
技术规范
Article number
6BK1942-0AA00-0AA0
6BK1942-0BA00-0AA0
HCS Rack4200 for 12 POM
HCS Rack4200 for 4 POM
General information
Product type designation
Rack4200 for 12 POMs
RACK4200 for 4 POMs
Installation type/mounting
Mounting type
Control cabinet backplane
Mounting position
Horizontal
Type of ventilation
Self ventilation or forced ventilation
Hardware configuration
Type of power output connectable
POM4220
Slots
● Number of slots
12
4
Interfaces
Interfaces/bus type
system interface
Isolation
Degree of pollution
2
EMC
EMC interference emission
Limit value in accordance with IEC 61000-6-4:2007 + A1:2011
Electrostatic discharge acc. to IEC 61000-4-2
4 kV contact discharge / 8 kV air discharge
Field-related interference acc. to IEC 61000-4-3
10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0... 2.7 GHz)
Degree and class of protection
IP degree of protection
IP20
Standards, approvals, certificates
CE mark
Yes
UL approval
RCM (formerly C-TICK)
KC approval
EAC (formerly Gost-R)
China RoHS compliance
reference designation according to IEC 81346-2 (2009)
K
Ambient conditions
Ambient temperature during operation
● min.
0 °C
● max.
55 °C
Ambient temperature during storage/transportation
● Storage, min.
-25 °C
● Storage, max.
70 °C
● Transportation, min.
● Transportation, max.
Air pressure acc. to IEC 60068-2-13
● Operation, min.
860 Pa
● Operation, max.
1 080 Pa
● Storage, min.
660 Pa
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
2 000 m
Relative humidity
● Operation at 25 ℃, max.
95 %
● Operation at 50 ℃, max.
50 %; 95 % at 25 °C, decreasing linearly to 50 % at 50°C
Vibrations
● Vibration resistance during operation acc. to IEC60068-2-6
10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g
● Vibration resistance during storage acc. to IEC60068-2-6
5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1 g
Shock testing
● Shock resistance during operation acc. to IEC60068-2-27
15 g / 11 ms / 3 shocks/axis
● Shock resistance during storage acc. to IEC60068-2-29
25 g / 6 ms / 1 000 shocks/axis
Dimensions
Width
488 mm
204 mm
Height
285 mm
Depth
293 mm
附件
The following accessories are available for the rack:
Fan Module:
One Fan Module supplies up to 4 Power Output Modules pluggedinto the rack. It is attached to the top.
The 24 V DC power supply is via a 2-core cable with a singleconnector (included in the scope of delivery) and is plugged in onthe rear bus board.
Blanking cover:
If not all slots in the rack are occupied by Power OutputModules, the free slots must be covered with a blanking cover.
The plate is secured with 1 screw at the top und 1 screw at thebottom.
武汉西门子低压断路器代理商,武汉西门子模块代理商,
5SL4232-8CC5SL4 2P D32 5SL4240-8CC5SL4 2PD40 5SL4250-8CC5SL4 2P D50 5SL4263-8CC5SL4 2PD63 5SL4314-8CC5SL4 3P D0.3 5SL4305-8CC5SL4 3PD0.5 5SL4301-8CC5SL4 3P D1 5SL4315-8CC5SL4 3PD1.6 5SL4302-8CC5SL4 3P D2 5SL4303-8CC5SL4 3PD3 5SL4304-8CC5SL4 3P D4 5SL4306-8CC5SL4 3PD6 5SL4308-8CC5SL4 3P D8 5SL4310-8CC5SL4 3PD10 5SL4313-8CC5SL4 3P D13 5SL4316-8CC5SL4 3PD16 5SL4320-8CC5SL4 3P D20 5SL4325-8CC5SL4 3PD25 5SL4332-8CC5SL4 3P D32 5SL4340-8CC5SL4 3P D40西门子武汉供应商电源供应 西门子武汉供应商电源供应